H820 User Manual 
This section is mainly about DTU settings.
DTU status: open and close DTU
DTU Serial setting
serial baudrate: support 300/1200/2400/4800/9600/19200/38400/57600/115200bps
serial parity: support none/odd/even
serial databits: support 7 bits and 8 bits
serial stopbit: support 1 bits and 2 bits
serial flow control: support hardware/software
DTU config
mode: can configure as client or server.
Protocol: support TCP/UDP
server 1~server 4: fill in the centre server IP or Domain name and port. If you
configure one server, the data will transfer to this server. If you configure one more
servers, the data will transfer to all the servers at the same time.
Send heart beat: open or close heart beat.
heart beat interval time: set interval time to send each heart beat
heart beat information: define the content of heart beat
ELinsTechnologyCo.,Limited
Tel:+8675529230581Email:sales@elins.comsales@szelins.comwww.szelins.comwww.elins.com
send delay time: send waiting time to send data.