connection is made.
<delay>
- The delay (in seconds) between <method> is triggered and the string is
being sent. 0 means that the string will not sent immediately.
< RegInfoString>
- The actually registration information packet being sent.
- Two variables could not used in string
3AT+KEEPALIVE=<Period>,<KeepAliveString>
<Period>
- The time (in seconds) between each keep alive packet is being sent. 0
means this feature is being off.
<KeepAliveString>
- The actually string being sent as a keep alive packet. Note: no variables
is supported in this string
4AT+IDLETIME=<time>
<time>
- The time (in minutes) requires to be idle (on both sides) in order to let the
DTU to disconnect itself from connection. (Keep alive and registration
information packet is not counted). 0 means the feature is disabled.
5AT+CLIENTCONFIG=<index>,<IpAddress>,<port>
<index>
- The index of the client configuration set.
<IpAddress>
- The IP address (in string) which the socket is going to connect.
<port>
‐TheTCP /IPport(innumber)whichthesocketisgoingtoconnect.
6AT+DTUID=<DTUID>
The command is used to set the DTU identifier for unit
<DTUID>
‐theDTUidentifiersetfortheunit
7AT+DATAMODE=<mode>
Set the format of the data packets that will sent thought-out the network
<mode>
‐ 0
(default) for the data the encapsulated with headers (format from the
customerdocment).
- 1 for the direct data mode, no packet header encapsulated.
8AT+SOCKETOPEN=<index>,<protocol>
<index>