D120 DTU Modem Quick Start
How to Change Baud Rate
Change CDMA Module Baud Rate
AT+iMCM //switch to at command mode
AT+IPR //query current baud rate
AT+IPR=n //setting a new baud rate
Note: n=0/2400/4800/9600/19200/38400/57600/115200 (the factory default value is 9600
Change TCP/IP Module Baud Rate
AT+i //switch to AT+I command mode
AT+iBDRF=n //below AT+I command should take effect after power down and on
AT+iBDRM=n
AT+iSNSI=”n,8,m,1,0” //m=n,o,e(no parity, odd parity, even parity), the parameters must use low case
AT+iPARS //parameter save
The relation with parameter to baud rate
n=3 2400
n=4 4800
n=5 9600
n=6 19200